Swordfish Plus

 

Swordfish Plus

The Swordfish pump control system provides fully integrated cascading pressure control for pump stations operating up to 6 pumps.

Easy to use and suitable for any type of pump or pump combination, the Swordfish controller is specifically designed to help improve the overall efficiency, operation and protection of multi-pump stations.

It offers both system and individual pump protection which can be configured to suit any system. Alarms are displayed on screen and fault resets can be conducted either on site or via remote control.

Features include:

  • An industry proven dedicated pump control system designed to operate fixed speed pumps.
  • Complete control package.
    • Connect power, wire in the pumps and attach the pressure tube.
  • Supplied equipment.
    • Swordfish+ controller
    • IP54 Enclosure
    • Mains Isolator
    • Circuit breakers
    • MEN power connections
    • 25Bar pressure transducer 4-20mA
  • Multiple control voltages.
  • Capable of operating up to 6 pumps.
  • Real English Menus with a 2 Line 16 characters LCD Display.     
  • Pump enabled and run indicators.
  • Easy navigation menu system with password access control.
  • For clarity Menus disappear when an option or function is not selected or required.
  • Simple push button actions to enable/disable or manually operate each pump.
  • Inbuilt settable time clock.
  • Remote Control capability via digital input or telemetry.
  • SCADA Compatible Modbus/RS485 for remote data acquisition, download or control.
  • Two control modes.
    • One Cut In and Cut Out pressure for all pumps with time delayed starting of pumps.
    • Individual Cut In and Cut Out pressures for each pump.
  • Data protection or user entry via access code.
  • Twelve programmable inputs for user selectable functionswith adjustable delay.
  • Four programmable voltage free outputs for BMS interfacing or user selectable output functions.
  • Selectable Duty /Standby and Backup pump operating mode options.
  • Programmable spin-up mode for any pump that has not recently run. Adjustable Interval & time.
  • Temporary mute of the buzzer on key press actions for silent operation. (Not essential)
  • Continuous display of the pressure
  • Optional Rotary Auto/Off/Manual switches.
    • Manual can be configured to one of two modes.
      • Indirect- The Swordfish+ will operate the pump and provide protection.
      • Direct- The pump switchgear is operated directly from the AOM switch. Provides further redundancy but bypasses protection.
  • Simple scaling and zeroing for all types of sensors or transducers.
  • Data logs for local or remote viewing.
    • Total system flow.
    • Resettable Hours runs and pump starts for each pump
    • Status of all inputs or outputs.
    • Highest pressure
    • Communications status
  • Fault logging.
  • User adjustable Low Pressure Setting with adjustable delay which performs a Low Pressure Shutdown.
  • User adjustable Cut In (Restart) Pressure setting.
    • Also has an adjustable next pump In (ON) delay timer
  • User adjustable Cut Out (Turn off pumps) Pressure setting.
    • Cut Out is set a pressure.
    • Also has an adjustable next pump Out (OFF) delay timer
  • User adjustable High Pressure setting with adjustable delay which performs a High Pressure Shutdown.
  • A High pressure shutdown displays the pressure that exceeded the limit until the system is reset.
  • Individual pump fault protection option with adjustable delay.
  • Individual pump protection option with auto-resetting and adjustable delay.
  •  Anti cycle options.
    • Pump minimum run time.
    • Maximum starts per hour.
  • System Restart Delay Timer.
  • System No Flow Input with adjustable timer.
  • Pump Rotation Options:
  • Normal Full Autorotation will occur during any system restart.
    • Fixed Pump Start. The same pumps starts on every restart.
    • Pump with the lowest hours to start next.
  • Optional independent Jockey pump.
  • Pause Input.
    • Two options available.
      • Pause all pumps including the Jockey pump.
      • Pause the main pumps and allow the Jockey pump to run.
  •  Low Level Input option.
    • Used with floats or similar on pressure applications. Displays "Paused - Low-Level".
  • User Access Code Features
  • Multiple Sensor interface
    • Sensor signals.
      • 0-20mA
      • 4-20mA
      • 0-10VDC
      • 0-5VDC
  • Telemetry
    • The Swordfish+ is capable of communicating with an external telemetry system based on digital Inputs and/or Outputs from other devices.
    • A serial communications port is provided for direct connection to SCADA or BMS system for access to the Swordfish+ operating parameters. This is via RS485 MODBUS RTU protocol. A full list of registers addresses can be provided.
    • Option interfaces can be provided such as.
      • Ethernet.
      • Multi Mode Fibre
      • Single Mode Fibre
  • Digital Outputs
    • The Swordfish+ has 4 programmable outputs that can be selected for a variety of functions. They are rated to 5 amps 240VAC with change over contacts. 
  • Digital Inputs
    • The Swordfish+ has 12 programmable voltage free inputs that can be selected for a variety of functions.
  • Four programmable Start and Stop times for system operation.

 

 

 

 